Protection Function:
Battery Overcharge and charge protection;
Battery open-circuited protection;
Load over-voltage protection;
Reversed charge protection at night;
Solar Cells reversed protection;
Battery reversed protection.
Specifications:
Model | PVSCM1230 | PVSCM2430 | PVSCM1230 | |
System rated voltage | 48V | 24V | 12V | |
MAX. Input power | 1500W | 750W | 360W | |
Current | Charge | 30A | 30A | 30A |
Discharge | 30A | 30A | 30A | |
Charge | Average charge | 57.6V±1% | 28.8V±1% | 14.4V±1% |
Recover | 53.2V±1% | 26.6V±1% | 13.3V±1% | |
Float charge | (54.0-55.2V)±1% | (27.0-27.6V)±1% | (13.5-13.8V)±1% | |
Temperature compensator | -72mV/℃ | -36mV/℃ | -18mV/℃ | |
Start voltage | 49.2±1% | 24.6V±1% | 12.3±1% | |
Over discharge | Switching off | 44.4V±1% | 22.2V±1% | 11.1V±1% |
Recover | 52.8V±1% | 26.4V±1% | 13.2V±1% | |
Over voltage | Switching off | 66V±1% | 33V±1% | 16.5V±1% |
Recover | 60V±1% | 30V±1% | 15V±1% | |
No-load current | ≤10mA | ≤10mA | ≤10mA | |
Solar control open voltage | ≤8V±1% | ≤4V ±1% | ≤2V±1% | |
Solar control shut voltage | ≥28V±1% | ≥14V±1% | ≥7V±1% | |
Max open circuit voltage | 100V | 50V | 25V | |
Display | LCD+LED | |||
Work temperature | -25℃~+55℃ | |||
Using altitude | ≤5500m(above 2000m need reduced the power) | |||
Size and weight | 180mmx107mmx55mm 0.95Kg |